MANOY® System Seal WP

Type 423

MANOY® System Seal WP

Type 428

MANOY® System Seal WP

Type 482

MANOY® System Seal WP

Type 487

TECHNICAL DATAS

outer sealing inner sealing outer sealing inner sealing
Motion Motion Motion Motion
rotary, partially static, partially linear rotary, partially static, partially linear rotary, partially static, partially linear rotary, partially static, partially linear
Direction of pressure Direction of pressure Direction of pressure Direction of pressure
unidirectional, bidirectional unidirectional, bidirectional unidirectional unidirectional
Operating pressure (MPa) Operating pressure (MPa) Operating pressure (MPa) Operating pressure (MPa)
40 40 40 40
Diameter range (mm) Diameter range (mm) Diameter range (mm) Diameter range (mm)
20 to 500 10 to 500 35 to 2000 35 to 2000
Housing Housing Housing Housing
non-split
(from 40 mm Ø)
non-split
(from 40 mm Ø)
split

split

Type 423 outer sealing
Motion rotary, partially static, partially linear
Direction of pressure unidirectional, bidirectional
Operating pressure (MPa) 40
Diameter range (mm) 20 to 500
Housing non-split
(from 40 mm Ø)
Type 428 inner sealing
Motion rotary, partially static, partially linear
Direction of pressure unidirectional, bidirectional
Operating pressure (MPa) 40
Diameter range (mm) 10 to 500
Housing non-split
(from 40 mm Ø)
Type 482 outer sealing
Motion rotary, partially static, partially linear
Direction of pressure unidirectional
Operating pressure (MPa) 40
Diameter range (mm) 35 to 2000
Housing split
Type 487 inner sealing
Motion rotary, partially static, partially linear
Direction of pressure unidirectional
Operating pressure (MPa) 40
Diameter range (mm) 35 to 2000
Housing split

APPLICATIONS

  • Developed for seal­ing of guide vanes 
  • Also usable on Kaplan blades and pivot pins 
  • Suit­able for water and/or grease lubrication

CHARACTERISTICS

  • Reli­able func­tion­al­ity if there is oscil­la­tion and vibra­tion on the system
  • Anti-twist design for smooth oper­a­tion even dur­ing change of rotat­ing dir­ec­tion with vibration 
  • Avail­able in any dia­met­er up to ca. 2,000 mm 
  • For ret­ro­fits the seals can be adap­ted to exist­ing install­a­tion dimensions

TEMPERATURE RANGE

From -20 to +200 °C

but depend­ent on the O-ring mater­i­al and ener­gizer elast­omer in each case.

MATERIALS

IDG stand­ard seal­ing ring material

  • U96

Ener­gizer elastomer

  • NBR

Mater­i­al descrip­tion and oth­er mater­i­als for wider applic­a­tions FIND OUT MORE >

The guide vanes con­trol the inflow of water in turbines.

These vanes run in slid­ing bear­ings. To give the bear­ings longer term pro­tec­tion from water infilt­ra­tion, the inner seal­ing MANOY® sys­tem seal WP, type 428, was developed for stand­ard specifications.

Type 487 with integ­ral scraper was designed for high spe­cific­a­tions due to abras­ive con­stitu­ents in the water and/or long inspec­tion inter­vals. The hous­ing for this seal must be open.

The pro­file dimen­sions of both ver­sions can be cus­tom­ized to adapt to exist­ing groove designs.